The following information is required for a new foundation.
Name. See: Common Parameters.
Description. See: Common Parameters.
Order Index. See: Common Parameters.
Default gap. This parameter is the default vertical distance between the top of the foundation and the base of the mast.
A positive value will place the base of the mast above the top of the foundation, while a negative value will place the base of the mast below the top of the foundation.

Minimum gap. This parameter is the smallest possible vertical distance between the top of the foundation and the base of the mast.
Maximum gap. This parameter is the largest possible vertical distance between the top of the foundation and the base of the mast.

Requires Length. This parameter must be ‘True’ or ‘False’. If the foundation is to have blank graphics and only one length, then this parameter must be ‘False’, in all other cases, this parameter must be ‘True’.
Template Type. See: Common Parameters.
When the Requires Length parameter is ‘False’, this parameter must be ‘Fixed’, in all other cases, this parameter must be ‘Fixed Selected by Allocation’.